SL400
Wireless Telemetry System - Signatrol UK
SL400
Wireless Radio Telemetry System
Now With Ethernet Connectivity |
|
The
SL400 system is a radio based wireless telemetry system. Ideal
for retro fitting a monitoring system into an existing installation
with minimum downtime and cost.
The
SL400 system comprises of remote radio transmitters that measure
temperature, relative humidity, low differential pressure,
mA or voltage signals and periodically transmits the values
back to a receiving base station. The radio transmitters operate
on the worldwide, license free frequency and have an output
power of only 10mW which does not interfere with other sensitive
electronic equipment but allows up to 1000m transmission range.
The
SL400 base stations can now be supplied with Ethernet connectivity.
This means that there is no longer a restriction on the distance
from the transmitters to the base station.
The
SL400-ETHERNET base station can be connected to your existing
Ethernet network in a convenient location to pick up the relevant
transmissions and the data passed over your network.
The
software supports up to 20 base stations.
Details
on the SL400 software can be found here |
|
| Specifications |
Common
To All Units |
| Power |
Internal
Battery |
| Battery
Life |
5
Years - 10 minute transmit rate |
| Temperature
Range |
-10°C
to +60°C |
| Transmission
Rates |
15,
30, 45, 60, 75, 90, 105, 120, 135 Seconds
10, 20, 30, 40, 50, 60, 70, 80, 90 Minutes
|
| Resolution |
|
| Range |
1000m
line of sight |
| Transmit
Frequency |
434.075Mhz
@ 10mW |
| Batteries |
Four
AA alkaline |
| Warranty |
1
Year |
| Ingress
Protection |
IP50
- SL401
IP67 all other models
|
| Online
Datasheet |
|
|
| Specifications |
SL400 |
| Description |
Receiving
Base Station With RS232 Connectivity |
| Resolution |
8
Bit or 16 Bit |
|
| |
| Specifications |
SL400-ETHERNET |
| Description |
Receiving
Base Station With Ethernet Connectivity |
| Resolution |
8
Bit or 16 Bit |
|
| |
| Specifications |
SL412-1,
SL412-2, SL412-4 |
| Measured
Parameter |
Temperature
and Relative Humidity |
| Sensor |
Rotronic
Hygroclip |
| Ranges |
-40°C
to +85°C
0 to 100 %RH |
| Resolution |
16
Bit |
| Accuracy |
Temperature:
±0.3°C
Relative
Humidity: ±1.5%RH
|
|
| |
| Specifications |
SL413-1,
SL413-2, SL413-4 |
| Measured
Parameter |
Temperature |
| Sensor |
Pt100 |
| Range |
-100°C
to +500°C (Maximum Span 500°C) |
| Resolution |
16
Bit (0.1°C) |
| Accuracy |
|
|
| |
| Specifications |
SL419 |
| Measured
Parameter |
Differential
Pressure |
| Input |
0-50pa |
| Resolution |
16
Bit |
| Accuracy |
|
|
|
|