SL709 Data logger - Signatrol UK

SL709
Dual Channel Pulse Input Data Logger

View Previous Data LoggerView Next Data Logger
The SL709 is a dual channel pulse data logger. The SL709 is commonly used to measure the switch output from flow meters although it can be used as a standard pulse counter. The SL709 will count up to 4096 counts in the predefined sample period. The SL709 can be connected direct to switches, or volt free contacts as well as electrical signals where the low level is less than 0.5VDC and the high signal is between 4.5VDC and 24VDC. As with all SL700 series data loggers, they are supplied with an internal battery giving up to 10 years battery life.
SL709 Dual Input Pulse Data Logger

Specifications
SL709
Power
Internal Battery
Battery Life
10 Years
Temperature Range
-40°C to +70°C
Channels
Two
Input
Volt Free Contact or
Voltage: Low = <+0.5VDC High = >+4.5 to +24VDC
Accuracy

±1 Pulse / Sample Period

Maximum Pulses / Sample Period
4095
Resolution

12 Bit

Number of Readings
SL709
21,500
SL709-128K
87,000
Sample Rate

8 seconds to once every 8 hours - Standard
25 readings per second using option battery pack

Ingress Protection
IP20
Software Alarms
No
Delayed Start
Yes
Stop When Full
Yes
Material
Noryl
Warranty
3 Years
Dimensions (LxWxH)
107mm x 74mm x 22mm
Download Software
Not Available
Online Datasheet
View Datasheets
Order Code
Standard 32K Memory
SL709
128K Memory
SL709-128K