The SL7000 data loggers have a very flexible combination of inputs from a single temperature up to 4 universal inputs each of which can be individually configured to accept any combination of the following input types:
- RTD / Pt100
- Thermocouple (Types J, K, T, R, S, B, N)
- mA (4-20mA 4/20mA)
- Volts
- mV
- Thermistors
- Slidewire
- Cu
- Ni
All SL7000 data loggers have an internal temperature sensor and a digital input which can be used as a trigger to start logging or as a pulse counter for interfacing with flow meters or other sensors with a pulse output.
An optional internal relative humidity sensor with ±2% accuracy is available on all units as well as an optional external temperature and relative humidity sensor. This gives a total of 9 channels - internal temperature, internal pulse counter, internal relative humidity, external temperature & relative humidity and either two or four universal inputs.
All SL7000 series data loggers are powered by their own, user replaceable battery, that has a typical life in excess of 6 years. Each SL7000 has enough memory to record up to 62,000 readings and the four universal channel data loggers can take 128,000 readings, at intervals from 1 second to 24 hours . Each data logger can be programmed to stop logging when the memory is full or over write the oldest reading.
The SL7000 features unprecedented accuracy, combining our extensive knowledge of instrumentation precision with data logging technology. High end resolution of 16 Bit for all universal inputs and a modular build ensures that the unit is competitively priced whatever the application.
An optional on-board LCD display shows selected channel information and the integral LED displays provide immediate scanning and alarm status information.
The data logger can be set to start logging immediately, start on an event (either a trigger event or the exercising of an external digital input) or start with the application of an external magnet (provided). This feature enables loggers to be set up in advance of the mission by a supervisor and to be launched at the start of the journey / log period by an operator.
The SL7000 series data loggers are connected to the computer via a USB cable (provided). It is possible to network up to 64 devices using regular USB hubs. All SL7000 series data loggers are supplied with TempIT-Pro software. More information on TempIT can be found by Clicking Here
The SL7000 is also available without the LCD option although the alarm LED's are still provided to indicate the alarm state of each channel - flashing GREEN if and alarm condition has not been encountered or RED if it has.
Product Specifications
|
Description
|
Detail
|
|
Input Variations
|
Internal Temperature and counter
Internal Temperature + RH and counter
Internal Temperature, 2 Channel Universal and counter
Internal Temperature + RH, 2 Channel Universal and counter
Internal Temperature, 4 Channel Universal and counter
Internal Temperature, RH, 4 Channel Universal and counter
+Additional External Temp and RH option on all versions
|
|
Universal Inputs
|
Pt 100: 2 or 3 Wire °C or °F (BS EN 60751/JIS1604)
Ni100, Ni120: 2 or 3 Wire °C or °F
Cu10, Cu100: 2 or 3 Wire °C or °F
Thermocouples Types J, K, T, R, S, B, N °C or °F
Thermistor (Various Types) °C or °F
4/20 mA Scaled in engineering units
±100mVdc Scaled in engineering units
(0 to 1)Vdc Scaled in engineering units
(0 to 10) Vdc Scaled in engineering units
Slidewire Scaled in engineering units (100 ohm to 10Kohm)
|
|
Measurement Resolution
|
All Universal Inputs - 16 Bit
Internal & External Temperature - 12 Bit
Internal & External Relative Humidity - 8 Bit
|
|
Counter Input
|
Used to start logging or as a counter. Maximum Count = 65535 per sample period. A current flowing into the counter pin >1 mA <10 mA or a Potential Free Contact (PFC) = logic '1'. Counts can be actual counts or scaled in engineering units.
Maximum frequency = 32768Hz.
|
| Log Interval |
1 Second to 24 hours for all channels |
Sample Methods
|
Point - The sampled measurement is stored directly to memory.
Averaging - The average value per period is stored
Maximum - The maximum value per period is stored
Minimum - The maximum value per period is stored |
|
Start Options
|
Programmable Delay Period (10 minutes to 1 year)
Start on external magnet swipe
Start when counter input goes high
Start on event trigger
|
|
Channel Indicators
|
8 Green LED's to indicate logging status changing to Red to indicate alarm conditions.
|
|
Communication Indicator
|
1 Yellow LED to indicate comms activity
|
|
Display
|
Optional 3.5 Digit LCD with channel indication and low battery warning. Continuous display with value updated every 4 to 255 seconds (programmable). Units displayable are °C, °F, mA, V, %
|
|
Communication Interface
|
USB Isolated (mini-USB 1B Male connector) - Cable Supplied
|
|
Universal Input Connector
|
14 Way 2 part plug/socket
|
|
External Temperature & RH Connector
|
6 Pin mini-Din
|
|
Cold Junction Compensation
|
Uses internal temperature sensor
|
|
Input
|
Accuracy - Full Scale Deflection (FSD)
|
|
|
± 0.5°C (-30°C to +70°C)
|
| External Temperature |
± 0.3°C @ 25°C
± 0.5°C over the range 0°C to +50°C
± 1.0°C over the range -30°C to 0°C and 50°C to 70°C
|
| Internal / External RH |
± 2.0%RH over 10%-90%
± 4.0% RH over the range 0-10% and 90-100%RH |
Pt 100 2 or 3 Wire
°C or °F |
± 0.1°C + 0.1% rdg |
| Ni100/Ni120/Cu100 |
± 0.2°C ± 0.1% rdg |
Cu10
0.00427 Coefficient |
± 3°C ± 0.5% rdg |
| Slidewire |
± 0.02% FSD |
| 4/20mA |
± 0.01% FSD (for Isolated Loops), accuracy may be reduced for non-isolated loops.
Some application may require the use of an external isolator (not supplied).
Maximum Volt drop in a 4/20mA loop = 4VDC
Will also accept 0/20mA signals |
| ±100mVdc |
± 0.01% FSD |
| 0/1Vdc |
± 0.01% FSD |
| 0/10Vdc |
± 0.01% FSD |
|
Thermocouples
(Types J, K, T & N)
|
± 0.1% FSD ± 0.5°C |
Thermocouples
(Types R,S & B) |
± 0.2% FSD ± 0.5°C |
| Thermistor (Various Types, °C or °F) |
Type dependent contact sales office for details |
| Measuring Ranges |
|
| Internal Temperature |
-30°C to +70°C (-22°F to +158°F) |
| Internal Relative Humidity |
0 to 100%RH |
| External Temperature |
-30°C to +70°C (-22°F to +158°F) |
| External Relative Humidity |
0 to 100%RH |
| RTD (Pt100) EN 60751 |
-200°C to +700°C (-328°F to +1292°F) |
| RTD (Pt100) JISC |
-100°C to +457°C (-148°F to +854°F) |
| Thermocouple Type K |
-200°C to +1370°C (-328°F to +2498°F) |
| Thermocouple Type J |
-200°C to +1200°C (-328°F to +2192°F) |
| Thermocouple Type T |
-200°C to +400°C (-328°F to +752°F) |
| Thermocouple Type S |
100°C to +1760°C (+212°F to +3200°F) |
| Thermocouple Type R |
100°C to +1760°C (+212°F to +3200°F) |
| Thermocouple Type B |
+700°C to 1820°C (+1292°F to +3308°F) |
| Thermocouple Type N |
-180°C to +1300°C (-292°F to +2372°F) |
| Ni120 |
-80°C to +230°C (-112°F to +446°F) |
| Ni100 |
-60°C to +180°C (-76°F to +356°F) |
| Cu10 |
-200°C to +260°C (-328°F to +500°F) |
| Cu100 |
-100°C to +260°C (-148°F to +500°F) |
| Thermistor (TH-001) |
-40°C to +140°C (-40°F to +284°F) |
| Slidewire |
0 to 100% |
| Millivolt (mV) |
-110mV to +110mV (Over Voltage protected to 24VDC) |
| 10 Volt |
0VDC to 11VDC (Over Voltage protected to 24VDC) |
| 1 Volt |
0VDC to 1.1VDC (Over Voltage protected to 24VDC) |
| 4/20mA |
0.1 to 21mA |
| Pulse Counter |
Up to 65,535 pulses per sample period |
|
General Specification
|
|
| Memory Size |
0 or 2 Universal Inputs - 62,000 Readings
4 Universal Inputs - 128,000 Readings |
| Memory Utilisation |
Wrap Around (First in, First Out) or Stop when Full (Default). |
| Battery |
Lithium AA (3.6V DC) 2.7 Ah User replaceable |
| Battery Life |
Depending on input configuration, typically 6 years with a sample rate > 2 minutes and LED flash rate > 30 second - Click below for detailed graph
|
| Ambient Operating Range |
-30°C to +70°C - Non LCD Display Version
-20°C to +50°C - LCD Display Version |
| Manifest Text (User) |
256 Characters |
| Manifest Text (Owner) |
256 Characters |
| Alarm Setpoints |
Independent High and Low, Latching per channel |
Alarm Trigger Time
|
Each Setpoint has an associated time. This time dictates the period the alarm must be continuously present before the alarm is raised. The options are 0 to 255 sample periods. |
Event Trigger
|
A programmable level per channel that will cause all channels to start recording when the input first crosses the threshold in the specified direction. An event can also be the exercising of an external digit signal or the activation of a magnetic swipe. |
| Low Battery Warning |
Low Battery displayed when battery life has less than one month to go. |
| Warranty |
2 Years |
| IP Rating |
IP50 |
| Enclosure Material |
ABS - Moulded from RoHS compliant material |
| UL Flame Rating |
94-VO at 0.059' wall
94-5VA at 0.098' wall
UL File Number: E56070
|
| Dimensions |
124mm (L) x 78mm (W) x 32mm (H) |
| Weight |
165gms |
| Online Data Sheet |
|
| Quickstart Guide |
|
| Operating Manual |
|
| Software |
|
| Animated Overview |
Click Here |
| Accessories |
|
| SL-ACC7000-01 |
External Temp/RH Probe |
| SL-ACC7000-02 |
Replacement Miniature USB connecting lead |
| SL-ACC7000-03 |
Replacement Lithium Thionyl Chloride Battery |
| SL-ACC7000-04 |
External power supply (cannot be used with ACC7000-01) |
| SL-ACC7000-05 |
Spare 14 way input connector |
| SL-ACC33 |
IP65 weatherproof enclosure |
| TempIT-Lite |
Operating Software (Free of charge) - requires version 4 or above |
| TempIT-Pro |
Upgrade to professional version |
| TempIT-HS |
High Security Version - Contact sales office for availability |
Note: All SL7000 data loggers are supplied with a USB communication lead, and magnetic fob for activating the magnetic start and a copy of TempIT-Pro.