SL7000 Data Loggers (Up To 4 Universal Channels)

The SL7000 data loggers have a very flexible combination of inputs from a single temperature up to 4 universal inputs each of which can be individually configured to accept most common sensors

  • High Performance At A Low Price
  • Accepts Most Commonly Available Sensors
  • Up To NINE Inputs
  • Supplied With TempIT-PRO Software - Worth £135!!

£499.00

Ex. VAT


ENQUIRE?

Email to a colleague

Download Data Sheet

Download Instruction Sheet

Download Software


The SL7000 data loggers have a very flexible combination of inputs from a single temperature up to 4 universal inputs each which means they can be individually configured with the software to accept any combination of the following input types: 

  • RTD / Pt100
  • Thermocouple (Types J, K, T, R, S, B, N) with isolated tip
  • 4/20mA
  • 0-10VDC
  • 0-100mV
  • Various Thermistors
  • Slidewire
  • Cu Sensors
  • Ni Sensors

All SL7000 data loggers have an internal temperature sensor and a digital input which can be used as a trigger to start logging or as a pulse counter for interfacing with flow meters or other sensors with a pulse output. 

An optional internal relative humidity sensor with ±2% accuracy is available on all units as well as an optional external temperature and relative humidity sensor. This gives a total of nine possible channels although it is unlikely all will be used at once:
  • Internal temperature
  • Internal pulse counter
  • Internal relative humidity
  • External temperature
  • External relative humidity sensor
  • And either two or four universal inputs

Which data logger

The part number is made up as follows:

The first digit is always a 7 as this is the series.

The next digit is 0 if no display is fitted or 1 if a display is fitted.

The next digit is always a 0

The last digit determines what options are fitted:

0 - Internal temperature only
1 - Internal Temperature and Internal Relative Humidity
2 - Two external, universal inputs,Internal Temperature
3 - Two external, universal inputs, Internal Temperature and Internal Relative Humidity
4 - Four external, universal inputs,Internal Temperature
5 - Four external, universal inputs, Internal Temperature and Internal Relative Humidity

Universal inputs are configured in the software to accept any of the following in any combination:

Pt100 (RTD), 3 wire
Thermocouple types J, K, T, R, S, B, N
Ni100, Ni120
Cu10
Thermistor
4/20mA
±100mV
0-1VDC
0-10VDC
Slidewire

All SL7000 series data loggers are currently supplied with a single computer licence of our TempIT-PRO software. Saving £135.00 

General Specifications

Power Internal Battery - Lithium AA (3.6V DC) 2.7 Ah user replaceable
Battery Life Depending on input configuration, typically 6 years with a sample rate > 2 minutes and LED flash rate > 30 second
Ambient Temperature -30°C to +70°C (-22°F to 158°F)
Number of Readings Stored 0 or 2 Universal Inputs - 62,000 Readings
4 Universal Inputs - 128,000 Readings
Memory Utilisation Wrap Around (First in, First Out) or Stop when Full (Default).
Sample Rate 1 Second to 24 hours for all channels
Sample Method Point - The sampled measurement is stored directly to memory.
Averaging - The average value per period is stored
Maximum - The maximum value per period is stored
Minimum - The maximum value per period is stored
Reusable When Memory Full Yes
Resolution All Universal Inputs - 16 Bit
Internal & External Temperature - 12 Bit
Internal & External Relative Humidity - 8 Bit
Waterproofing IP50 - Ingress of dust is not entirely prevented and the device is not protected at all for moisture ingress.
Please see waterproof enclosures in the accessories section if the product is to be placed outside.
Start Logging Options

Programmable Delay Period (10 minutes to 1 year)
Start on external magnet swipe
Start when counter input goes high
Start on event trigger

There are no STOP logging functions. The logger will take a programmable number of readings or log until the memory is full.

Software Alarms Yes, high and low alarms can be specified in the software
Intrinsic Safety No
Channel Indicators 8 Green LED's to indicate logging status changing to Red to indicate alarm conditions.
Communication Interface USB Isolated (mini-USB 1B Male connector) - Cable Supplied
Material ABS - Moulded from RoHS compliant material
Dimensions 124mm (L) x 78mm (W) x 32mm (H)
Weight 165 grams
UL Flame Rating 94-VO at 0.059' wall
94-5VA at 0.098' wall
UL File Number: E56070
Warranty 3 Year (excluding battery)

Measuring Ranges

Internal Temperature -30°C to +70°C (-22°F to +158°F)
Internal Humidity 0 to 100%RH
Plug In External Temperature Sensor           -30°C to +70°C (-22°F to +158°F)
Plug In External Humidity Sensor 0 to 100%RH
RTD / Pt100 to EN 60751 -200°C to +700°C (-328°F to +1292°F)
RTD (Pt100) JISC -100°C to +457°C (-148°F to +854°F)
Thermocouple Type K -200°C to +1370°C (-328°F to +2498°F)
Thermocouple Type J -200°C to +1200°C (-328°F to +2192°F)
Thermocouple Type T -200°C to +400°C (-328°F to +752°F)
Thermocouple Type S 100°C to +1760°C (+212°F to +3200°F)
Thermocouple Type R 100°C to +1760°C (+212°F to +3200°F)
Thermocouple Type B +700°C to 1820°C (+1292°F to +3308°F)
Thermocouple Type N -180°C to +1300°C (-292°F to +2372°F)
Ni120 -80°C to +230°C (-112°F to +446°F)
Ni100 -60°C to +180°C (-76°F to +356°F)
Cu10 -200°C to +260°C (-328°F to +500°F)
Cu100 -100°C to +260°C (-148°F to +500°F)
Thermistor (TH-001) -40°C to +140°C (-40°F to +284°F)
Slidewire 0 to 100%
MilliVolt -110mV to +110mV (Over Voltage protected to 24VDC) scaled in engineering units
0-10VDC 0VDC to 11VDC (Over Voltage protected to 24VDC) scaled in engineering units                                                                                                    
0-1VDC 0VDC to 1.1VDC (Over Voltage protected to 24VDC) scaled in engineering units
4/20mA 0.1 to 21mA scaled in engineering units
Pulse Counter Maximum Count = 65535 per sample period.
Maximum Frequency = 32678Hz.
Logic 0 < 0.9Vdc.
Logic 1 > 1.9Vdc
Trigger: Negative Edge
User settable filter link 32768Hz or 50Hz. (default: 32768Hz)
Can be used with common collector outputs when using an external shunt resistor.

Measuring Accuracies

Internal Temperature ± 0.5°C (-30°C to +70°C)
Internal Humidity ± 2.0%RH over 10%-90%
± 4.0% RH over the range 0-10% and 90-100%RH
Plug In External Temperature Sensor ± 0.3°C @ 25°C
± 0.5°C over the range 0°C to +50°C
± 1.0°C over the range -30°C to 0°C and 50°C to 70°C
Plug In External Humidity Sensor ± 2.0%RH over 10%-90%
± 4.0% RH over the range 0-10% and 90-100%RH
RTD / Pt100 to EN 60751 ± 0.1°C + 0.1% rdg
RTD (Pt100) JISC ± 0.1°C + 0.1% rdg
Thermocouple Type K ± 1.9°C
Thermocouple Type J ± 1.7°C
Thermocouple Type T ± 0.9°C
Thermocouple Type S ± 2.3°C
Thermocouple Type R ± 2.3°C
Thermocouple Type B ± 2.4°C
Thermocouple Type N ± 1.8°C
Ni120 ± 0.2°C ± 0.1% rdg
Ni100 ± 0.2°C ± 0.1% rdg
Cu10 ± 3°C ± 0.5% rdg
Cu100 ± 0.2°C ± 0.1% rdg
Thermistor (TH-001) Type dependent, please contact sales office for more details
Slidewire ± 0.02% FSD
MilliVolt ± 0.01% FSD
0-10VDC ± 0.01% FSD                                                                                                                                                    
0-1VDC ± 0.01% FSD
4/20mA ± 0.01% FSD (for Isolated Loops), accuracy may be reduced for non-isolated loops.
Some applications may require the use of an external isolator (not supplied).
Maximum Volt drop in a 4/20mA loop = 4VDC
Will also accept 0/20mA signals
Pulse Counter 20ppm